{"created":"2024-08-27T03:14:04.994270+00:00","id":2000128,"links":{},"metadata":{"_buckets":{"deposit":"52dadaa3-7519-4837-a84a-10f7f376a0ca"},"_deposit":{"created_by":18,"id":"2000128","owner":"18","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"2000128"},"status":"published"},"_oai":{"id":"oai:osaka-dent.repo.nii.ac.jp:02000128","sets":["1686642104765:1:63:64"]},"author_link":[],"control_number":"2000128","item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2024-03-27"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"大阪歯科大学"},{"subitem_degreegrantor_language":"en","subitem_degreegrantor_name":"Osaka Dental University"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"34408","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(歯学)","subitem_degreename_language":"ja"}]},"item_10006_description_7":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"In modern prosthodontic treatment, digital technology is rapidly gaining popularity in terms of facilitating treatment planning and the design and manufacture of prosthesis. Recently, technology to integrate three-dimensional data of facial structures and dentition has also been developed. We investigated the accuracy of two dental facial scan systems guided by an extraoral scan body currently available in Japan. The null hypothesis was that there was no difference in the accuracy of the three-dimensional virtual facial model between the two systems. The manikin head on which the maxillary arch model was mounted was scanned by a reference high precision laser scanner (FARO) and two dental face scanners, FACE HUNTER (FH) and FREEDOM F (FF). The scans from FH and FF were superimposed on the reference scan from FARO using the iterative closest point (ICP) method, and the mean deviation of the arch model was calculated. The accuracy (trueness and precision) was 0.403 ± 0.120 mm for the FH and 3.053 ± 0.568 mm for the FF, when compared with the FARO. The accuracy of the system was better in the FH than in the FF.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"乙第1666号"}]},"item_10006_relation_14":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.18905/jodu.58.1_29","subitem_relation_type_select":"DOI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"Journal of Osaka Dental University. 2024, 58(1), p. 29-39."}]}]},"item_10006_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2024 The Author(s)","subitem_rights_language":"en"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"西堀, 邦彦","creatorNameLang":"ja"},{"creatorName":"ニシボリ, クニヒコ","creatorNameLang":"ja-Kana"},{"creatorName":"Nishibori, Kunihiko","creatorNameLang":"en"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-03-27"}],"filename":"otu_1666_ab.pdf","filesize":[{"value":"238 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"論文内容要旨・審査結果要旨","objectType":"abstract","url":"https://osaka-dent.repo.nii.ac.jp/record/2000128/files/otu_1666_ab.pdf"},"version_id":"7ea8d38b-43c2-4644-bdd4-b735b16f492e"},{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-03-27"}],"filename":"otu_1666_fulltext.pdf","filesize":[{"value":"717 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"学位論文","objectType":"fulltext","url":"https://osaka-dent.repo.nii.ac.jp/record/2000128/files/otu_1666_fulltext.pdf"},"version_id":"986b9eb6-975a-48d8-be26-c66b97a1b371"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Accuracy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Virtual patient","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Virtual facebow","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Face scanne","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Computer-aided design","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"An in vitro study of the accuracy of a three-dimensional virtual patient representation guided by an extraoral scan body","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"An in vitro study of the accuracy of a three-dimensional virtual patient representation guided by an extraoral scan body","subitem_title_language":"en"},{"subitem_title":"口腔外スキャンボディを使用した3次元仮想患者表現の精確さに関する in vitro 研究","subitem_title_language":"ja"}]},"item_type_id":"10006","owner":"18","path":["64"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2024-06-27"},"publish_date":"2024-06-27","publish_status":"0","recid":"2000128","relation_version_is_last":true,"title":["An in vitro study of the accuracy of a three-dimensional virtual patient representation guided by an extraoral scan body"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2024-08-28T02:36:20.445427+00:00"}