{"created":"2024-08-28T03:19:59.832119+00:00","id":2000131,"links":{},"metadata":{"_buckets":{"deposit":"fa7b32d5-c7de-4c18-9227-2546c360b5d4"},"_deposit":{"created_by":18,"id":"2000131","owner":"18","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"2000131"},"status":"published"},"_oai":{"id":"oai:osaka-dent.repo.nii.ac.jp:02000131","sets":["1686642104765:1:1724813534049:1724813728424"]},"author_link":[],"control_number":"2000131","item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2024-06-26"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"大阪歯科大学"},{"subitem_degreegrantor_language":"en","subitem_degreegrantor_name":"Osaka Dental University"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"34408","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(歯学)","subitem_degreename_language":"ja"}]},"item_10006_description_7":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Purpose: We superimposed the digital scan data of a maxillary complete denture fabri­cated by microwave curing with the digital scan data of a physical working model, then investigated the change in fit by adjusting interference areas.\nMethods: The scan data of 10 maxillary complete dentures fabricated by microwave cur­ing and 10 working models were superimposed to investigate changes in fit according to adjustment of interference areas. The interference areas were then machined and re­evaluated.\nMain results: The fit rates were 60.1±4.8% immediately after polymerization, 69.3±5.9%for the first round of grinding, and 73.4±6.0% for the second round of grinding. One­way analysis of variance showed that the compliance rate significantly increased with grind­ing. Additionally, multiple comparisons were made between uncut and first grinding, first and second grinding, and uncut and second grinding; the fit rate significantly increased in all cases. Repeated measurements and analysis of variance regarding deviation be­tween the working model and the finished denture showed that the deviation was signifi­cantly reduced by grinding and the overall fit was improved; however, there were differ­ences among the sites, and not all sites displayed similar improvement.\nPrincipal conclusions: By superimposing the stereolithography data of a working model on the mucosal surface of a maxillary complete denture using a three­dimensional scan­ner, we were able to improve the fit.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"乙第1669号"}]},"item_10006_relation_14":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.18905/jodu.58.1_85","subitem_relation_type_select":"DOI"}},{"subitem_relation_name":[{"subitem_relation_name_text":"Journal of Osaka Dental University. 2024, 58(1), p. 85-93."}]}]},"item_10006_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2024 The Author(s)","subitem_rights_language":"en"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"楊, 林","creatorNameLang":"ja"},{"creatorName":"ヤン, リン","creatorNameLang":"ja-Kana"},{"creatorName":"Yang, Lin","creatorNameLang":"en"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-08-28"}],"filename":"otu_1669_ab.pdf","filesize":[{"value":"244 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"論文内容要旨・審査結果要旨","objectType":"abstract","url":"https://osaka-dent.repo.nii.ac.jp/record/2000131/files/otu_1669_ab.pdf"},"version_id":"58872b91-7347-4386-b050-fc943525c25c"},{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-10-30"}],"filename":"otu_1669_fulltext.pdf","filesize":[{"value":"880 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"学位論文","objectType":"fulltext","url":"https://osaka-dent.repo.nii.ac.jp/record/2000131/files/otu_1669_fulltext.pdf"},"version_id":"dc565af6-5659-463d-932e-71ce63e407d6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Digital dentistry","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Complete denture","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Edentulous","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Scanner","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Improvement of prosthetic device fit using a 3D scanner","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Improvement of prosthetic device fit using a 3D scanner","subitem_title_language":"en"},{"subitem_title":"3Dスキャナーを利用した補綴装置の適合性の改善","subitem_title_language":"ja"}]},"item_type_id":"10006","owner":"18","path":["1724813728424"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2024-08-28"},"publish_date":"2024-08-28","publish_status":"0","recid":"2000131","relation_version_is_last":true,"title":["Improvement of prosthetic device fit using a 3D scanner"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2024-10-30T02:43:12.256210+00:00"}