{"created":"2023-05-15T13:57:35.105278+00:00","id":297,"links":{},"metadata":{"_buckets":{"deposit":"7b8745c6-a4af-4e76-b373-0662e131bd70"},"_deposit":{"created_by":16,"id":"297","owners":[16],"pid":{"revision_id":0,"type":"depid","value":"297"},"status":"published"},"_oai":{"id":"oai:osaka-dent.repo.nii.ac.jp:00000297","sets":["1686642104765:1:45:49"]},"author_link":["765","764"],"item_10006_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"テーパー角および厚さの異なるジルコニアを用いたテレスコープクラウンの外冠の破折強度"}]},"item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2021-03-05"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"大阪歯科大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"34408","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(歯学)"}]},"item_10006_description_10":{"attribute_name":"学位授与年度","attribute_value_mlt":[{"subitem_description":"2020年度","subitem_description_type":"Other"}]},"item_10006_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The objective of this study was to clarify the influence of the half taper angle and thickness of the zirconia secondary crown on its fracture strength. Y-TZP was used for both primary and secondary crown. Samples were prepared at the half taper angles of 2° and 4° and a secondary crown thickness of 0.5 and 1.0 mm (n=7). The secondary crown was restored on the primary crown and the fracture strength was determined by loading all specimens until fracture using a universal testing machine. The load applied at the time of secondary crown fracture was regarded as fracture strength. Based on the analysis of variance, although the fracture strength at 1.0-mm thickness was significantly greater than that at 0.5-mm thickness, the taper angle had no influence on the fracture strength.","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第910号"}]},"item_10006_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"柴田, 駿亮"},{"creatorName":"シバタ, シュンスケ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"764","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shibata, Shunsuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"765","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-08-16"}],"displaytype":"detail","filename":"kou_910_txt.pdf","filesize":[{"value":"342.6 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"学位論文","url":"https://osaka-dent.repo.nii.ac.jp/record/297/files/kou_910_txt.pdf"},"version_id":"c923834a-d59f-4b5b-9e19-03f56303f36c"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-04-23"}],"displaytype":"detail","filename":"kou_910.pdf","filesize":[{"value":"212.5 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"論文内容要旨・審査結果要旨","url":"https://osaka-dent.repo.nii.ac.jp/record/297/files/kou_910.pdf"},"version_id":"b4817f80-facc-46c1-a551-9c7bf75cf4da"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Telescopic crowns|Y-TZP| Zirconia| Fracture strength","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Fracture strength of telescopic zirconia secondary crowns of different taper and thickness","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Fracture strength of telescopic zirconia secondary crowns of different taper and thickness"}]},"item_type_id":"10006","owner":"16","path":["49"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-04-23"},"publish_date":"2021-04-23","publish_status":"0","recid":"297","relation_version_is_last":true,"title":["Fracture strength of telescopic zirconia secondary crowns of different taper and thickness"],"weko_creator_id":"16","weko_shared_id":-1},"updated":"2023-05-15T15:29:03.770557+00:00"}