{"created":"2023-05-15T13:57:24.049157+00:00","id":80,"links":{},"metadata":{"_buckets":{"deposit":"75630266-3792-4311-ac80-07b5435d39ca"},"_deposit":{"created_by":14,"id":"80","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"80"},"status":"published"},"_oai":{"id":"oai:osaka-dent.repo.nii.ac.jp:00000080","sets":["1686642104765:1:6:8"]},"author_link":["379","334"],"item_10006_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"⻭科⽤コーンビーム CT のピクセル値の評価について"}]},"item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2015-03-06"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"大阪歯科大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"34408","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(歯学)"}]},"item_10006_description_10":{"attribute_name":"学位授与年度","attribute_value_mlt":[{"subitem_description":"2014年度","subitem_description_type":"Other"}]},"item_10006_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"コーンビームCT(CBCT)画像の画素濃度を、多列検出器CT(MDCT)で撮影した画像のCT値に基づいて評価した。試験チューブをファントムの中央に単独で置いた場合、画素濃度、CT値ともに造影剤濃度に対して線形相関があった。しかし、CBCT画像の画素濃度とMDCT画像のCT値は一致しなかった。中央の試験チューブ周囲に濃度1〜20%の造影剤が入ったチューブ5本を歯列に見立てて置いた場合、MDCT画像ではCT値に影響を受けなかったが、CBCTでは画素濃度が低くなる場合があった。また、造影剤濃度が高くなるにつれて画素濃度はわずかに低下した。頸椎を視野の外側になるようにファントムの側へ置いた場合、MDCT画像ではCT値に影響を受けなかったが、CBCT画像では頸椎を置かなかった場合に比べて画素濃度が低下することがあった。各CBCTのデータグラフは、MDCTのCT値が500〜1300の間で特に高い線形相関がみられた。","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第742号"}]},"item_10006_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"中島, 有佳⼦"},{"creatorName":"ナカシマ, ユカコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"379","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakashima, Yukako","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"334","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-08-01"}],"displaytype":"detail","filename":"kou_742_txt..pdf","filesize":[{"value":"369.6 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"学位論文","url":"https://osaka-dent.repo.nii.ac.jp/record/80/files/kou_742_txt..pdf"},"version_id":"830cdf62-4c30-4f0b-ab3d-4966fbc9d834"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-08-01"}],"displaytype":"detail","filename":"kou_742.pdf","filesize":[{"value":"247.8 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"論文内容要旨・審査結果要旨","url":"https://osaka-dent.repo.nii.ac.jp/record/80/files/kou_742.pdf"},"version_id":"2c2b5772-4971-4ed3-96cc-b3fa3b4ef990"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Iothalamic Acid","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"頸椎","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"画像ファントム","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"マルチスライスCT","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"*コーンビームCT","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"画素値","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"撮像視野","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"管状器具","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"歯学","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Evaluation of pixel density in the images of cone-beam computed tomography","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Evaluation of pixel density in the images of cone-beam computed tomography"}]},"item_type_id":"10006","owner":"14","path":["8"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-08-01"},"publish_date":"2016-08-01","publish_status":"0","recid":"80","relation_version_is_last":true,"title":["Evaluation of pixel density in the images of cone-beam computed tomography"],"weko_creator_id":"14","weko_shared_id":14},"updated":"2023-05-15T14:12:27.002131+00:00"}