Item type |
学位論文 / Thesis or Dissertation(1) |
公開日 |
2017-04-19 |
本文言語 |
|
|
言語 |
eng |
タイトル |
|
|
タイトル |
Effects of taper and space settings of telescopic Ce-TZP/A crowns on retentive force and settling |
著者 |
中川, 修佑
Nakagawa, Shusuke
|
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
telescopic crowns|CAD/CAM|Ce-TZP/A|taper|retentive force |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_db06 |
|
資源タイプ |
doctoral thesis |
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
The aim of this study was to investigate the effect of the taper and space setting of using Ce-TZP/A on retentive force and secondary crown settling. The taper were 2°, 4°, and 6°, and the space settings were 0 and 10 μm. The applied loads were 50 and 100 N. The taper had a significant effect on retentive force and settling at both loads (p<0.05). The space settings did not have a significant effect on retentive force or settling at either load (p<0.05). The taper of the telescopic crowns and the load affected the retentive force and the settling. |
学位名 |
|
|
学位名 |
博士(歯学) |
学位授与機関 |
|
|
|
学位授与機関識別子Scheme |
kakenhi |
|
|
学位授与機関識別子 |
34408 |
|
|
学位授与機関名 |
大阪歯科大学 |
学位授与年月日 |
|
|
学位授与年月日 |
2017-03-10 |
学位授与番号 |
|
|
学位授与番号 |
甲第791号 |