WEKO3
アイテム
口腔外スキャンボディを使用した3次元仮想患者表現の精確さに関する in vitro 研究
https://osaka-dent.repo.nii.ac.jp/records/2000128
https://osaka-dent.repo.nii.ac.jp/records/2000128415d968c-353e-41df-875e-713345d657f1
名前 / ファイル | ライセンス | アクション |
---|---|---|
論文内容要旨・審査結果要旨 (238 KB)
|
|
|
学位論文 (717 KB)
|
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2024-06-27 | |||||||||||
本文言語 | ||||||||||||
言語 | eng | |||||||||||
タイトル | ||||||||||||
タイトル | An in vitro study of the accuracy of a three-dimensional virtual patient representation guided by an extraoral scan body | |||||||||||
言語 | en | |||||||||||
タイトル | ||||||||||||
タイトル | 口腔外スキャンボディを使用した3次元仮想患者表現の精確さに関する in vitro 研究 | |||||||||||
言語 | ja | |||||||||||
著者 |
西堀, 邦彦
× 西堀, 邦彦
|
|||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Accuracy | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Virtual patient | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Virtual facebow | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Face scanne | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Computer-aided design | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||||||||
資源タイプ | doctoral thesis | |||||||||||
アクセス権 | ||||||||||||
アクセス権 | open access | |||||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | In modern prosthodontic treatment, digital technology is rapidly gaining popularity in terms of facilitating treatment planning and the design and manufacture of prosthesis. Recently, technology to integrate three-dimensional data of facial structures and dentition has also been developed. We investigated the accuracy of two dental facial scan systems guided by an extraoral scan body currently available in Japan. The null hypothesis was that there was no difference in the accuracy of the three-dimensional virtual facial model between the two systems. The manikin head on which the maxillary arch model was mounted was scanned by a reference high precision laser scanner (FARO) and two dental face scanners, FACE HUNTER (FH) and FREEDOM F (FF). The scans from FH and FF were superimposed on the reference scan from FARO using the iterative closest point (ICP) method, and the mean deviation of the arch model was calculated. The accuracy (trueness and precision) was 0.403 ± 0.120 mm for the FH and 3.053 ± 0.568 mm for the FF, when compared with the FARO. The accuracy of the system was better in the FH than in the FF. | |||||||||||
言語 | en | |||||||||||
学位名 | ||||||||||||
言語 | ja | |||||||||||
学位名 | 博士(歯学) | |||||||||||
学位授与機関 | ||||||||||||
学位授与機関識別子Scheme | kakenhi | |||||||||||
学位授与機関識別子 | 34408 | |||||||||||
言語 | ja | |||||||||||
学位授与機関名 | 大阪歯科大学 | |||||||||||
言語 | en | |||||||||||
学位授与機関名 | Osaka Dental University | |||||||||||
学位授与年月日 | ||||||||||||
学位授与年月日 | 2024-03-27 | |||||||||||
学位授与番号 | ||||||||||||
学位授与番号 | 乙第1666号 | |||||||||||
権利 | ||||||||||||
言語 | en | |||||||||||
権利情報 | © 2024 The Author(s) | |||||||||||
関連情報 | ||||||||||||
識別子タイプ | DOI | |||||||||||
関連識別子 | https://doi.org/10.18905/jodu.58.1_29 | |||||||||||
関連情報 | ||||||||||||
関連名称 | Journal of Osaka Dental University. 2024, 58(1), p. 29-39. |