WEKO3
アイテム
3Dスキャナーを利用した補綴装置の適合性の改善
https://osaka-dent.repo.nii.ac.jp/records/2000131
https://osaka-dent.repo.nii.ac.jp/records/20001319c12fe8a-2a0f-43f9-be70-080e8e5d4aff
名前 / ファイル | ライセンス | アクション |
---|---|---|
論文内容要旨・審査結果要旨 (244 KB)
|
|
|
学位論文 (880 KB)
|
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2024-08-28 | |||||||||||
本文言語 | ||||||||||||
言語 | eng | |||||||||||
タイトル | ||||||||||||
タイトル | Improvement of prosthetic device fit using a 3D scanner | |||||||||||
言語 | en | |||||||||||
タイトル | ||||||||||||
タイトル | 3Dスキャナーを利用した補綴装置の適合性の改善 | |||||||||||
言語 | ja | |||||||||||
著者 |
楊, 林
× 楊, 林
|
|||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Digital dentistry | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Complete denture | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Edentulous | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Scanner | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||||||||
資源タイプ | doctoral thesis | |||||||||||
アクセス権 | ||||||||||||
アクセス権 | open access | |||||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | Purpose: We superimposed the digital scan data of a maxillary complete denture fabricated by microwave curing with the digital scan data of a physical working model, then investigated the change in fit by adjusting interference areas. Methods: The scan data of 10 maxillary complete dentures fabricated by microwave curing and 10 working models were superimposed to investigate changes in fit according to adjustment of interference areas. The interference areas were then machined and reevaluated. Main results: The fit rates were 60.1±4.8% immediately after polymerization, 69.3±5.9%for the first round of grinding, and 73.4±6.0% for the second round of grinding. Oneway analysis of variance showed that the compliance rate significantly increased with grinding. Additionally, multiple comparisons were made between uncut and first grinding, first and second grinding, and uncut and second grinding; the fit rate significantly increased in all cases. Repeated measurements and analysis of variance regarding deviation between the working model and the finished denture showed that the deviation was significantly reduced by grinding and the overall fit was improved; however, there were differences among the sites, and not all sites displayed similar improvement. Principal conclusions: By superimposing the stereolithography data of a working model on the mucosal surface of a maxillary complete denture using a threedimensional scanner, we were able to improve the fit. |
|||||||||||
言語 | en | |||||||||||
学位名 | ||||||||||||
言語 | ja | |||||||||||
学位名 | 博士(歯学) | |||||||||||
学位授与機関 | ||||||||||||
学位授与機関識別子Scheme | kakenhi | |||||||||||
学位授与機関識別子 | 34408 | |||||||||||
言語 | ja | |||||||||||
学位授与機関名 | 大阪歯科大学 | |||||||||||
言語 | en | |||||||||||
学位授与機関名 | Osaka Dental University | |||||||||||
学位授与年月日 | ||||||||||||
学位授与年月日 | 2024-06-26 | |||||||||||
学位授与番号 | ||||||||||||
学位授与番号 | 乙第1669号 | |||||||||||
権利 | ||||||||||||
言語 | en | |||||||||||
権利情報 | © 2024 The Author(s) | |||||||||||
関連情報 | ||||||||||||
識別子タイプ | DOI | |||||||||||
関連識別子 | https://doi.org/10.18905/jodu.58.1_85 | |||||||||||
関連情報 | ||||||||||||
関連名称 | Journal of Osaka Dental University. 2024, 58(1), p. 85-93. |